Approved Constructions
CEILINGS
Ceiling Joints
OMEGA profile with screw cover strip
OMEGA profile with PVC cover section
OMEGA profile with screw cover profile or PVC cover section
Requirement: B-0 Class
Requirement: B-15 Class
Material: FIPRO®
Thickness: 10 mm
Junction: Deckhead mounting section
Construction: Detached steel construction
Sound reduction: 28 dB (estimated value)
Approved by:
Bureau Veritas
MED EC
USCG
Transport Canada
Germanischer Lloyd
Material: FIPRO® MS
Thickness: 19 mm
Junction: Deckhead mounting section
Construction: Detached steel construction
Sound reduction: 31 dB (estimated value)
Approved by:
Bureau Veritas
MED EC
USCG
Transport Canada
Det Norske Veritas
Germanischer Lloyd
Ceiling joint
Requirement: B-0 Class
Material: FIPRO® or FIPRO® MS
Thickness: 16 mm
Junction: Deckhead mounting section
Construction: Detached steel construction
Sound reduction: 29 dB (estimated value)
Approved by:
Bureau Veritas
MED EC
USCG
More joining sections see chapter Profiles.
Non-combustibility is one of the requirements for the use of interior construction panels in shipbuilding. This is tested in accordance with IMO Resolution A799 (19). FIPRO® has passed all tests and is approved by marine safety authorities and classification companies as a „non-combustible construction material“.
Extensive tests of bulkheads and claddings have been performed with FIPRO®. You can find a selection of approved designs in the following presentations. Certificates are available on request.